Part of our iHaaS deep-dive series. New to HaaS? Start here.
Quick answer: Warehouse temperature and humidity mapping places loggers in a grid across the floor and at several heights, records at a short fixed interval for at least a week, and finds the hot, cold and humid spots. WHO guidance suggests loggers every 5 to 10 m, stacked at low, middle and high levels, logging every 1 to 15 minutes for at least seven days in ambient warehouses. Once you know where the extremes are, a permanent monitoring grid (we use one terminal every 6 to 8 m, two levels above 4 m) keeps watch on them.
Most warehouses have a thermometer by the office door. It tells you about the office door. The pallets under the roof, the racks by the dock and the corner behind the dehumidifier each live in their own climate, and the only way to know them is to measure them.
At ATMOSIScience®, we make humidity-conditioning materials and run the HaaS monitoring system that sits alongside them. This guide covers how to plan a mapping grid, how it differs from a monitoring grid, and a worked layout for a 1,200 m² room.
Mapping vs monitoring: two jobs, two grids
They sound alike, but they answer different questions.
- Mapping is a study. The World Health Organization defines it as the documented measurement of the temperature and/or relative humidity distribution within a storage area, including identification of hot and cold spots (WHO Technical Supplement 8, Temperature mapping of storage areas). It's dense, temporary and run to a protocol.
- Monitoring is continuous. It watches the places the map flagged, alerts when something drifts, and builds the long record you'll show an auditor or a customer.
WHO says it plainly: the purpose of finding hot and cold spots is to identify where the monitoring sensors should preferentially go. Map first, then monitor smart.
What the WHO mapping guidance actually says
WHO's technical supplement was written for time- and temperature-sensitive pharmaceutical products, and it says the guidance applies to any space designed for storing them or other temperature-sensitive products. The points that drive your sensor count:
| Topic | WHO Supplement 8 guidance |
|---|---|
| Horizontal grid | Loggers in a grid along length and width, every 5 to 10 m. In very large facilities this can be up to 20 or 30 m. Adjust for layout, shelving, airflow and where product is actually stored |
| Heights, ceiling 3.6 m or less | High, medium and low at each grid point, for example floor level, 1.2 m and 3.0 m |
| Heights, ceiling above 3.6 m | Vertical arrays at bottom, middle (multiple) and top. For a 6 m space: 0.3, 1.8, 3.6 and 5.4 m |
| Recording interval | The same on every logger, typically 1 to 15 minutes, with the same start time on all units |
| Duration | Warehouses and ambient areas: at least seven consecutive days, including five working days and two weekend days. Cold rooms and freezer rooms: 24 to 72 hours, or longer if justified |
| Doors | If door openings are part of the study, define their frequency and duration. Log door openings, or keep an access log |
| Seasons | Hot and cold spots can differ significantly between summer and winter, so determine them seasonally |
| Re-mapping | Periodically (for example every three years), after significant changes to the store or its equipment, or when monitoring shows unexplained variability |
| Logger calibration | NIST-traceable 3-point calibration with an error of no more than ±0.5 °C at each point, with certificates included in the report |
WHO also flags that high-bay pallet racking is especially prone to temperature stratification and should be mapped over its full working height (full text of Supplement 8).
Our deployment rules for a monitoring grid
When we deploy HaaS, we start from our deployment principles and adjust them to the site:
- One temperature and humidity terminal every 6 to 8 m.
- Ceilings over 4 m get two levels of terminals, upper and lower.
- Terminals mounted at 1.5 m height.
- One gateway per 400 m², on Ethernet, with its Bluetooth antenna pointed toward the monitored room.
- One energy data collector per piece of mechanical and electrical equipment, and one infrared linkage controller per air conditioner.
Our minimum system is five terminals, one gateway, two energy data collectors (one on the dehumidifier, one on the humidifier) and one infrared linkage controller for the air conditioner.
Why fewer levels than a mapping study? Because the job is different. The map has already told you where the extremes are. The monitoring grid needs enough coverage to catch drift across the room, plus the upper level to catch the warm air that collects near the roof.
Where the risk hides
A grid alone isn't enough. Before you finalize positions, walk the room and mark these:
- Heating and cooling components. WHO asks you to record air outlets, ceiling fans, heaters and cooling units, and to define zones that shouldn't hold product, such as areas close to cooling coils, cold air streams or heat sources.
- The top of the racks. Warm air rises and sits there. In high-bay storage, this is where stratification shows up.
- Doors and docks. Every opening brings in outside air, along with its humidity. Put a point near each dock door, and log opening times so you can line them up with the spikes.
- Outside walls and the roof. They follow the weather, so they swing more than the middle of the room.
- Existing control sensors. WHO asks you to record where the room's own thermostats and monitoring sensors sit. If your control sensor is in the coolest corner, the rest of the room runs warmer than the setpoint says.
Humidity follows temperature. A cold spot near an outside wall is often your highest-RH spot too, and the first place condensation will show. For that physics, see our dew point guide.
Choosing a logging interval
The interval decides two things: whether you catch short events, and how long the device's memory lasts.
| Device and memory | Interval | Memory lasts | Good for |
|---|---|---|---|
| HaaS Mini, 260,000 records | 1 min (example setting) | about 180 days | Door-event studies, short sharp swings |
| HaaS Mini, 260,000 records | 5 min | about 900 days | A WHO-style mapping study with room to spare |
| HaaS Mini, 260,000 records | 15 min | about 2,700 days | The longest interval WHO lists for mapping |
| HaaS Box Pro (Bluetooth) or Box Plus, 8,760 records | 30 min | 182.5 days | Routine room monitoring through a gateway |
The math is simple: records × interval ÷ 1,440 minutes per day. For example, 260,000 × 5 ÷ 1,440 = 902.8 days. A seven-day mapping study at 5 minutes uses only 7 × 24 × 12 = 2,016 records per logger. At long intervals, memory isn't the limit: the Mini's built-in battery is rated for 1 year, so plan recharging into any long deployment.
For a formal mapping study, use terminals with a settable interval so every logger runs the same 1 to 15 minute schedule. For routine monitoring, our gateway reports every 30 minutes. When data completeness matters most, as in our climate-room tests, we upload every 10 minutes.
Worked example: a 1,200 m² storage room
Say the room is 40 m by 30 m, with 6 m clear height and racking along both long walls. Two air conditioners, one dehumidifier.
Step 1: the mapping study (WHO method)
- Grid at 10 m: 40 ÷ 10 = 4 columns, 30 ÷ 10 = 3 rows, so 12 grid points.
- Heights: the ceiling is above 3.6 m, so use WHO's 6 m example: 0.3, 1.8, 3.6 and 5.4 m. That's 4 loggers per point.
- Total: 12 × 4 = 48 loggers. At a tighter 5 m grid it would be 8 × 6 = 48 points and 192 loggers, so start at 10 m and add points where racking or airflow demands it.
- Add: one point at each dock door, plus points next to each air conditioner and the dehumidifier outlet.
- Run: at least 7 consecutive days at 5 minutes, same start time on every logger, with door openings logged. Repeat in the opposite season.
Step 2: the permanent monitoring grid (our rules)
- Positions: 6 columns × 5 rows = 30 positions, about 6.7 m apart along the 40 m side and 6 m apart along the 30 m side. Both are inside the 6 to 8 m rule. The minimum at 8 m would be 5 × 4 = 20.
- Levels: the ceiling is over 4 m, so two levels: the lower at 1.5 m, the upper near the top of the stored load. 30 × 2 = 60 terminals. Move positions onto the hot and cold spots the map found.
- Gateways: our rule of thumb gives 1,200 ÷ 400 = 3. The gateway's rated open-area coverage is about 300 m², which gives 1,200 ÷ 300 = 4. Racks aren't open area, so plan on 4 and confirm with a signal check during the site survey. Each gateway takes up to 50 Bluetooth devices, so 60 terminals across 4 gateways is 15 each, well inside capacity.
- Equipment: 3 energy data collectors (two air conditioners, one dehumidifier) and 2 infrared linkage controllers (one per air conditioner).

From the map to a monitoring system that acts
Once terminals are on the hot and cold spots, the data needs somewhere to go. Our HaasLink platform handles three things a warehouse team actually uses:
- Spatial statistics. Temperature and humidity across the space, so you see the room as a map, not a list.
- Dynamic deviation curves. Each zone against its target, over time. Drift shows up as a widening gap, long before an alarm.
- Alarms and linkage. Alerts by SMS, voice call or email, and triggers that can switch an air conditioner or dehumidifier through the linkage controllers.
Pair the grid with humidity-conditioning materials and you're no longer asking the HVAC to do everything. Materials hold the baseline, and powered equipment runs when the data says it's needed.
How the install runs
Our on-site deployment follows five stages: test preparation (survey and test plan), device preparation (select and function-test devices), on-site deployment preparation (issue deployment drawings), on-site deployment (install to the drawings, commission, add devices in the HaaS App), and data association (configure scenarios and devices on the platform, then run functional tests). The full project process is in From Pilot to Proof.

Frequently asked questions
How many data loggers do I need for warehouse temperature mapping?
Under WHO guidance, place loggers every 5 to 10 m in a grid, then multiply by the number of heights. Ceilings of 3.6 m or less need three heights; taller spaces need a vertical array, such as four heights in a 6 m room. A 40 m × 30 m room on a 10 m grid with four heights needs 48 loggers before you add door and equipment points.
How long should a warehouse mapping study run?
WHO suggests at least seven consecutive days for warehouses and ambient storage, including five working days and two weekend days. Cold rooms and freezer rooms can be 24 to 72 hours, or longer if justified.
What logging interval should I use for temperature mapping?
WHO says the interval should be the same on every logger, typically between 1 and 15 minutes. Five minutes is a practical middle: a seven-day study uses about 2,000 records per logger.
At what height should humidity sensors be installed?
For ongoing monitoring we mount terminals at 1.5 m and add an upper level when the ceiling is over 4 m. For a mapping study, follow the WHO vertical layout, such as floor level, 1.2 m and 3.0 m in a room 3.6 m tall or lower.
How often should a warehouse be re-mapped?
WHO gives every three years as an example, plus after significant changes to the store, its loading pattern or its equipment, and whenever monitoring shows unexplained variability. Seasonal mapping helps too, since hot and cold spots shift between summer and winter.
Get a sensor plan for your floor
Send us the floor size, ceiling height and what's stored. We'll lay out the grid and the gateways.
Prefer email? info@atmosiscience.com
Sources: World Health Organization, TRS 961 Annex 9, Supplement 8: Temperature mapping of storage areas (May 2015); full text (PDF). Worked layouts are our own calculations.